Absolute Maximum Ratings
Voltage on I/O pins relative to Vss
Voltage on VDD supply relative to Vss
Voltage on VDDQ supply relative to Vss
Note: Stresses greater than those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This is
stress rating only, and functional operation of the device at these or any other conditions above those indicated in the operational
sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect reliability.
DC operating Conditions
Operating Temperature (Ambient)
Storage Temperature (Plastic)
Short Circuit Output Current
Note:
1. Case temperature is measured at top and center side of any DRAMs.
2. t
CASE
> 85°C t
REFI
= 3.9 μs
3. All DRAM specification only support 0°C < t
CASE
< 85°C
DC Electrical Characteristics and Operating Conditions
(T
CASE
= 0 °C ~ 85 °C; V
DDQ
= 1.8V ± 0.1V; V
DD
= 1.8V ± 0.1V, See AC Characteristics)
Supply Voltage, I/O Supply Voltage
Input High (Logic1) Voltage
Input Low (Logic0) Voltage
Note:
1. Inputs are not recognized as valid until VREF stabilizes.
2. VREF is expected to be equal to 0.5 V DDQ of the transmitting device, and to track variations in the DC level of the same.
Peak-to-peak noise on VREF may not exceed 2% of the DC value.
Environmental Parameters
Module Operating Temperature Range (ambient)
Operating Humidity (relative)
Storage Temperature (Plastic)
Storage Humidity (without condensation)
Barometric Pressure (operating & storage)
Note:
1. Stresses greater than those listed may cause permanent damage to the device. This is a tress rating only, and device
functional operation at or above the conditions indicated is not implied. Exposure to absolute maximum rating conditions for
extended periods may affect reliability.
2. Up to 9850 ft.
3. The component maximum case temperature shall not exceed the value specified in the component spec.